<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>環境さんぷる &#187; サービス</title>
	<atom:link href="http://shell.peach.ne.jp/aoyama/archives/category/%e3%82%b5%e3%83%bc%e3%83%93%e3%82%b9/feed" rel="self" type="application/rss+xml" />
	<link>http://shell.peach.ne.jp/aoyama</link>
	<description>WordPress 2.9.2</description>
	<lastBuildDate>Fri, 30 Jul 2010 08:13:43 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<language>ja</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>HDT725032VLAT80が壊れた</title>
		<link>http://shell.peach.ne.jp/aoyama/archives/58</link>
		<comments>http://shell.peach.ne.jp/aoyama/archives/58#comments</comments>
		<pubDate>Fri, 07 Nov 2008 13:06:11 +0000</pubDate>
		<dc:creator>aoyama</dc:creator>
				<category><![CDATA[FreeBSD]]></category>
		<category><![CDATA[サービス]]></category>
		<category><![CDATA[機材]]></category>

		<guid isPermaLink="false">http://shell.peach.ne.jp/aoyama/archives/58</guid>
		<description><![CDATA[FreeBSD6.x/7.xで利用していたドライブがエラーを出したようだ。
テストマシンでのsmartctlによる抜粋データは以下のようなもの。
160GBプラッタ2枚のHDDのはずだが、それが脆いのかなぁ。
とりあえず代替のドライブがHDP725050GLAT80になるけど取り替えておいた。
そろそろIDEマシンをどうにかするべきか考えといけないのか・・・。
また壊れたら代替ドライブの入手が困難になりそうだ。
この余波でZFS環境での作業がちっとも進んでいません(汗)
代替ドライブ：

Device Model:     Hitachi HDP725050GLAT80
Firmware Version: GM4OA42A
User Capacity:    500,107,862,016 bytes
故障ケース１：

Device Model:     Hitachi HDT725032VLAT80
Firmware Version: V54OA4NA
User Capacity:    320,072,933,376 bytes  

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   016    Pre-fail  Always       -       0
  2 Throughput_Performance  0x0005   100   100   050    [...]]]></description>
			<content:encoded><![CDATA[<p>FreeBSD6.x/7.xで利用していたドライブがエラーを出したようだ。<br />
テストマシンでのsmartctlによる抜粋データは以下のようなもの。<br />
160GBプラッタ2枚のHDDのはずだが、それが脆いのかなぁ。<br />
とりあえず代替のドライブがHDP725050GLAT80になるけど取り替えておいた。<br />
そろそろIDEマシンをどうにかするべきか考えといけないのか・・・。<br />
また壊れたら代替ドライブの入手が困難になりそうだ。<br />
この余波でZFS環境での作業がちっとも進んでいません(汗)</p>
<p>代替ドライブ：</p>
<pre id="ex">
Device Model:     Hitachi HDP725050GLAT80
Firmware Version: GM4OA42A
User Capacity:    500,107,862,016 bytes</pre>
<p>故障ケース１：</p>
<pre id="ex">
Device Model:     Hitachi HDT725032VLAT80
Firmware Version: V54OA4NA
User Capacity:    320,072,933,376 bytes  

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   016    Pre-fail  Always       -       0
  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      -       0
  3 Spin_Up_Time            0x0007   132   132   024    Pre-fail  Always       -       325 (Average 241)
  4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       -       36
  5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       -       9
  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0005   100   100   020    Pre-fail  Offline      -       0
  9 Power_On_Hours          0x0012   099   099   000    Old_age   Always       -       7452
 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       36
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       347
193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always       -       347
194 Temperature_Celsius     0x0002   157   157   000    Old_age   Always       -       38 (Lifetime Min/Max 20/47)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       11
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       -       2
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       -       0  

Error 134 occurred at disk power-on lifetime: 7158 hours (298 days + 6 hours)
  When the command that caused the error occurred, the device was active or idle.  

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 01 40 22 11 e1  Error: UNC 1 sectors at LBA = 0x01112240 = 17900096  

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 01 40 22 11 e1 00      00:07:31.900  READ DMA
  c8 00 08 57 22 11 e1 00      00:07:31.900  READ DMA
  c8 00 01 3f 22 11 e1 00      00:07:27.100  READ DMA
  c8 00 04 7b 88 11 e1 00      00:07:27.100  READ DMA
  c8 00 04 3f 22 11 e1 00      00:07:22.300  READ DMA</pre>
<p>故障ケース２：</p>
<pre id="ex">
Device Model:     Hitachi HDT725032VLAT80
Firmware Version: V54OA4NA
User Capacity:    320,072,933,376 bytes  

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   016    Pre-fail  Always       -       0
  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      -       0
  3 Spin_Up_Time            0x0007   124   124   024    Pre-fail  Always       -       291 (Average 311)
  4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       -       205
  5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       -       51
  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0005   100   100   020    Pre-fail  Offline      -       0
  9 Power_On_Hours          0x0012   099   099   000    Old_age   Always       -       8134
 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       205
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       540
193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always       -       540
194 Temperature_Celsius     0x0002   157   157   000    Old_age   Always       -       38 (Lifetime Min/Max 18/47)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       83
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       -       0  

Error 1 occurred at disk power-on lifetime: 29 hours (1 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle
.  

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 01 10 01 ea ef  

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  fe a2 01 10 01 0a e0 02      00:03:32.700  [VENDOR SPECIFIC]
  fe a1 00 00 00 00 a0 02      00:03:32.700  [VENDOR SPECIFIC]
  fe a6 50 60 00 00 a0 00      00:03:32.500  [VENDOR SPECIFIC]
  c1 00 00 00 00 00 a0 02      00:03:32.500  [VENDOR SPECIFIC]
  fe a6 50 60 00 00 a0 00      00:03:32.400  [VENDOR SPECIFIC]</pre>
]]></content:encoded>
			<wfw:commentRss>http://shell.peach.ne.jp/aoyama/archives/58/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>FreeBSD 7.0がリリースされました</title>
		<link>http://shell.peach.ne.jp/aoyama/archives/38</link>
		<comments>http://shell.peach.ne.jp/aoyama/archives/38#comments</comments>
		<pubDate>Thu, 28 Feb 2008 11:56:04 +0000</pubDate>
		<dc:creator>aoyama</dc:creator>
				<category><![CDATA[FreeBSD]]></category>
		<category><![CDATA[IPv6]]></category>
		<category><![CDATA[iSCSI]]></category>
		<category><![CDATA[サービス]]></category>

		<guid isPermaLink="false">http://shell.peach.ne.jp/aoyama/archives/38</guid>
		<description><![CDATA[詳細はリリースアナウンスをみてくださいな。デュアルコア以上のマシンならいれる価値はあると思う。個人的興味はもちろんZFSとiSCSIですな。
さそっく手元のマシンを順次7.0リリースに置き換えています。
これでやっと7.0Betaとかなくなる。
ZFSは vm.kmem_size=&#8221;402653184&#8243; ぐらいは確保しないと使いものにならないっぽい。うちのマシンは384～512MBを目安に割り当てています。なんというか慢性的にメモリが足りないです。VirtualServerとかは1GB割りてるといい感じかも？
iSCSIはまだ試してなかったり＾＾；
]]></description>
			<content:encoded><![CDATA[<p>詳細は<a target="_blank" href="http://www.freebsd.org/releases/7.0R/announce.html">リリースアナウンス</a>をみてくださいな。デュアルコア以上のマシンならいれる価値はあると思う。個人的興味はもちろんZFSとiSCSIですな。</p>
<p>さそっく手元のマシンを順次7.0リリースに置き換えています。<br />
これでやっと7.0Betaとかなくなる。</p>
<p>ZFSは vm.kmem_size=&#8221;402653184&#8243; ぐらいは確保しないと使いものにならないっぽい。うちのマシンは384～512MBを目安に割り当てています。なんというか慢性的にメモリが足りないです。VirtualServerとかは1GB割りてるといい感じかも？</p>
<p>iSCSIはまだ試してなかったり＾＾；</p>
]]></content:encoded>
			<wfw:commentRss>http://shell.peach.ne.jp/aoyama/archives/38/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>ちょこっと手こずったが公開してみた</title>
		<link>http://shell.peach.ne.jp/aoyama/archives/35</link>
		<comments>http://shell.peach.ne.jp/aoyama/archives/35#comments</comments>
		<pubDate>Sun, 24 Feb 2008 18:17:28 +0000</pubDate>
		<dc:creator>aoyama</dc:creator>
				<category><![CDATA[FreeBSD]]></category>
		<category><![CDATA[IPv6]]></category>
		<category><![CDATA[Postfix]]></category>
		<category><![CDATA[サービス]]></category>

		<guid isPermaLink="false">http://shell.peach.ne.jp/aoyama/archives/35</guid>
		<description><![CDATA[メールサーバをPostfix+Dovecot+MySQL+PostfixAdminの構成でIPv6有効で作りました。
これを選んだ理由はSMTP認証をDovecot側のDB参照で出きる事です。sendmailでもがんばればできそうだけど、PostfixAdminの改造コストのがはるかに低いだろうとの思惑から＾＾；
MilterがIPv6受け付けなかったり、
ソケットのパーミッションにはまったり、
Dovecotの認証キャッシュにのって変更されなかったり、
PostfixAdmin2.2.0rc1にバグがあって素直に動かなかったり、
concatで無理やりパス作ってみたり、
400文字を超えるクエリとか作ってみたり、
気晴らしに日本語リソース作ってみたり。
ひとつ欠点というか仕様？だけどDovecotが複数のIPにバインドできないみたいだな。
]]></description>
			<content:encoded><![CDATA[<p>メールサーバをPostfix+Dovecot+MySQL+PostfixAdminの構成でIPv6有効で作りました。</p>
<p>これを選んだ理由はSMTP認証をDovecot側のDB参照で出きる事です。sendmailでもがんばればできそうだけど、PostfixAdminの改造コストのがはるかに低いだろうとの思惑から＾＾；</p>
<p>MilterがIPv6受け付けなかったり、<br />
ソケットのパーミッションにはまったり、<br />
Dovecotの認証キャッシュにのって変更されなかったり、<br />
PostfixAdmin2.2.0rc1にバグがあって素直に動かなかったり、<br />
concatで無理やりパス作ってみたり、<br />
400文字を超えるクエリとか作ってみたり、<br />
気晴らしに日本語リソース作ってみたり。</p>
<p>ひとつ欠点というか仕様？だけどDovecotが複数のIPにバインドできないみたいだな。</p>
]]></content:encoded>
			<wfw:commentRss>http://shell.peach.ne.jp/aoyama/archives/35/feed</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>せっかくアップしたのに2.3.3が出ちゃった</title>
		<link>http://shell.peach.ne.jp/aoyama/archives/22</link>
		<comments>http://shell.peach.ne.jp/aoyama/archives/22#comments</comments>
		<pubDate>Wed, 06 Feb 2008 16:02:18 +0000</pubDate>
		<dc:creator>aoyama</dc:creator>
				<category><![CDATA[サービス]]></category>

		<guid isPermaLink="false">http://shell.peach.ne.jp/aoyama/archives/22</guid>
		<description><![CDATA[アップグレード手順は簡単です。
WordPress2.3.3の展開したファイルをFileZillaのSFTPを使って全部アップしました。
]]></description>
			<content:encoded><![CDATA[<p><a target="_blank" href="http://ja.wordpress.org/upgrade/">アップグレード手順</a>は簡単です。</p>
<p>WordPress2.3.3の展開したファイルを<a target="_blank" href="http://filezilla-project.org/">FileZilla</a>のSFTPを使って全部アップしました。</p>
]]></content:encoded>
			<wfw:commentRss>http://shell.peach.ne.jp/aoyama/archives/22/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>WordPress ME 2.2.3 から JA 2.3.2に変更</title>
		<link>http://shell.peach.ne.jp/aoyama/archives/21</link>
		<comments>http://shell.peach.ne.jp/aoyama/archives/21#comments</comments>
		<pubDate>Mon, 04 Feb 2008 00:06:40 +0000</pubDate>
		<dc:creator>aoyama</dc:creator>
				<category><![CDATA[サービス]]></category>

		<guid isPermaLink="false">http://shell.peach.ne.jp/aoyama/archives/21</guid>
		<description><![CDATA[さんぷるにこだわってもあまり意味はないのだけど。
とりあえず最新ってことで＾＾；
]]></description>
			<content:encoded><![CDATA[<p>さんぷるにこだわってもあまり意味はないのだけど。</p>
<p>とりあえず最新ってことで＾＾；</p>
]]></content:encoded>
			<wfw:commentRss>http://shell.peach.ne.jp/aoyama/archives/21/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
